KYN28-12 REMOVABLE AC METAL-CLAD SWITCHGEAR

High Voltage Switchgear

KYN28-12 REMOVABLE AC METAL-CLAD SWITCHGEAR
KYN28-12 REMOVABLE AC METAL-CLAD SWITCHGEAR

KYN28-12 REMOVABLE AC METAL-CLAD SWITCHGEAR

Features

The KYN28-12(GZS1) Removable AC Metal-clad Switchgear(hereinafter referred to as "switchgear") is suitable for three-phase AC 50Hz power system. It is used for receiving and distributing electrical energy and controlling, protecting, and monitoring circuits.

The KYN28-12(GZS1) Removable AC Metal-clad Switchgear(hereinafter referred to as “switchgear”) is suitable for three-phase AC 50Hz power system. It is used for receiving and distributing electrical energy and controlling, protecting, and monitoring circuits.
The newly introduced high-current, high-breaking switchgear can also be used independently for high-voltage generator outlets. This product complies with the standards: GB3906 “3~35kV AC Metal-Enclosed Switchgear,” IEC60694&GBT11022 “Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards,” IEC62271-200″ AC Metal-Enclosed Switchgear and Control Equipment with Rated Voltages Above 1 kV up to and Including 52 kV.”

Ambient Condition:
AmbientAir Temperature: Maximum temperature +40°C, Minimum temperature-15°C
Humidity Conditions:Daily average relative humidity:≤95%,Daily average water vapor pressure does not exceed 2.2kPa, Monthly average
relative humidity:≤90%,Monthly average water vapor pressure does not exceed 1.8kPa
Altitude: 2500m and below
Seismic Intensity: Not exceeding 8 degrees
The ambient air should not be subject to corrosive or flammable gases, steam, or other obvious pollution. No places with constant severe
vibrations. If used beyond the normal conditions specified in GB3906, it should be negotiated between the user and the manufacturer.

Ordering Information (must be specified when ordering) 
1. Main circuit scheme number, purpose, single-line system diagram, arrangement diagram, and distribution room layout.
2. Auxiliary circuit wiring schematic, terminal arrangement diagram.
3. Model, specifications, and quantity of eletrical components inside the switchgear.
4. Requirements for control, measurement, and protection functions of the switchgear, as well as other interlocking and automatic device
requirements.
5. If busbar bridging is required between switchgear or incoming cabinets, provide specific requirements such as rated current-carrying capacity,
span, height above ground, etc.
6. If accessories or spare parts are needed, specify the type and quantity.
7. If the switchgear is used in special environmental conditions, provide detailed explanations when ordering.

Inquiry Now